How to measure dryer vent length
- Find the starting point. Pull the dryer out and find where the flexible transition hose joins the duct at the wall or floor. Measure from there, not from the dryer.
- Measure each straight section. Use a tape on exposed duct in a basement, attic or utility room. For duct hidden in a wall, measure the route on both sides of the wall and add them.
- Count every elbow. Note whether each is a 90° or a 45°, and whether it is a standard adjustable elbow or a smooth long radius sweep.
- Stop at the outside hood. The hood itself adds nothing under the code.
- Enter the numbers in the calculator above.
What counts toward the length
Inspectors call it the equivalent length: the length of the duct from its connection to the transition duct to the outlet terminal outside, plus an allowance for every bend. Bends count because air loses pressure turning a corner, and a dryer's blower can only push so hard. A run of 20 ft with three standard 90° elbows counts as 35 ft, the same as 35 ft of straight duct.
Three things are left out of the count:
- The transition duct. The flexible piece between the dryer and the duct in the wall is excluded from the length. It may be up to 8 ft long, in one piece, listed and labeled to UL 2158A, and it may not be concealed inside walls, floors or ceilings.
- The outlet hood. The IRC gives the outside cover no length allowance. Some dryer makers do: one Whirlpool chart takes 6 ft off for an angled hood compared with a box hood.
- Straight couplings. A plain joint between two straight sections adds nothing.
Dryer vent length with elbows: equivalent length chart
The IRC uses a table that depends on how tight the bend is. The same eight values appear in every edition from 2009 to 2024. A standard adjustable or mitered elbow counts as 5 ft. A smooth bend with a wider radius counts as little as 1 ft 6 in, which makes long radius sweeps a simple way to win back length.
| Fitting (4 in. duct) | Counts as (equivalent length) |
|---|---|
| 90° elbow, standard (4 in. radius mitered or segmented) | 5 ft |
| 45° elbow, standard (4 in. radius mitered or segmented) | 2 ft 6 in |
| 90° smooth bend, 6 in. radius | 1 ft 9 in |
| 45° smooth bend, 6 in. radius | 1 ft |
| 90° smooth bend, 8 in. radius | 1 ft 7 in |
| 45° smooth bend, 8 in. radius | 1 ft |
| 90° smooth bend, 10 in. radius | 1 ft 6 in |
| 45° smooth bend, 10 in. radius | 9 in |
Add these lengths to your straight duct, or subtract them from 35 ft. Both give the same answer.
Close-turn or space-saver elbows are tighter than the 4 in. radius in the table, and the table has no row for them. This calculator counts each one as a standard elbow at 5 ft, which may be too generous. Ask your inspector for a firm ruling.
Maximum dryer vent length by number of elbows
Under the IRC, the longest straight duct a dryer vent can have is the length limit minus the allowance for its elbows. With standard 90° elbows that is 30 ft with one elbow, 25 ft with two, 20 ft with three and 15 ft with four.
| 90° elbows | IRC 2012 to 2024, standard elbows | IRC 2012 to 2024, 10 in. radius sweeps | IRC 2006 and 2009, standard elbows |
|---|---|---|---|
| 0 | 35 ft | 35 ft | 25 ft |
| 1 | 30 ft | 33 ft 6 in | 20 ft |
| 2 | 25 ft | 32 ft | 15 ft |
| 3 | 20 ft | 30 ft 6 in | 10 ft |
| 4 | 15 ft | 29 ft | 5 ft |
Worked examples
Laundry closet on an outside wall. 6 ft of straight duct and two standard 90° elbows.
6 + 5 + 5 = 16 ft equivalent. That leaves 19 ft of the 35 ft limit.
Basement dryer venting up and out through the rim joist. 22 ft of straight duct, three standard 90° elbows and one 45°.
22 + 15 + 2.5 = 39 ft 6 in. That is 4 ft 6 in over. Swapping the four standard elbows for 10 in. radius sweeps brings it to 22 + 4.5 + 0.75 = 27 ft 3 in, which passes.
Second floor laundry venting through the roof. 28 ft of straight duct and two standard 90° elbows.
28 + 10 = 38 ft, 3 ft over the code limit. Swapping both elbows for 10 in. radius sweeps brings it to 28 + 3 = 31 ft, which passes.
Maximum dryer vent length by brand
The IRC lets the dryer's own installation instructions set the maximum length. The building official needs a copy of the instructions for your make and model at the inspection before the walls are closed. Most full size dryers allow longer runs than the 35 ft code default with 4 in. rigid metal duct. These figures come from each maker's published manual for the models shown:
| Brand and manual | 0 elbows | 1 elbow | 2 elbows | 3 elbows | 4 elbows |
|---|---|---|---|---|---|
| WhirlpoolElectric dryer instructions W10443041B, box or louvered hood | 64 ft | 54 ft | 44 ft | 35 ft | 27 ft |
| MaytagWhirlpool Corp. gas and electric dryer instructions W10904260B, supplied for Maytag YMEDB765FC, box or louvered hood | 64 ft | 54 ft | 44 ft | 35 ft | 27 ft |
| LGLG venting help page, standard models, 4 in. wall cap | 65 ft | 55 ft | 47 ft | 36 ft | 28 ft |
| GEElectric dryer instructions Pub. 31-16135, 4 in. dampened hood | 90 ft | 60 ft | 45 ft | 35 ft | 25 ft |
| FrigidaireInstallation manual A28709001 (2024), gas and electric, 4 in. hood | 90 ft | 60 ft* | 45 ft | 35 ft | n/a |
| SamsungDV45DG6000 user manual (2024), 4 in. hood | 80 ft | 68 ft | 57 ft | 47 ft | n/a |
n/a: not listed in that manual. *The Frigidaire manual prints 15.9 m next to 60 ft. The 60 ft figure matches GE's chart for the same setup, so the metric figure looks like the misprint. Some makers also sell long vent models rated for well over 100 ft. Their manuals list the exact figures.
Manufacturer tables work differently from the code. They list a maximum length for 0, 1, 2, 3 or 4 elbows, and often a separate column for each hood style. The elbows are already allowed for in each row, so you compare your duct length against the row that matches your setup. Choose My dryer's manual in the calculator and it does exactly that.
If you are buying a dryer for a long run, check the vent table in the installation instructions before you buy. They are usually posted on the maker's website under the model number.
How to fix a dryer vent that is too long
- Replace standard elbows with long radius sweeps. Under the 2009 to 2024 IRC, each 90° goes from 5 ft to as little as 1 ft 6 in, so three swaps win back 10 ft 6 in. The 2006 edition counts every bend the same, so this does not help there.
- Cut out bends. Two 45° elbows used to jog around an obstacle count as 5 ft. Rerouting to drop the jog is often less work than it looks.
- Exit through a closer wall. The shortest path to outside beats any fitting upgrade.
- Check the dryer's manual. Your model may allow the length you already have. If its limit is shorter than the code's, follow the manual.
- Add a dryer exhaust duct power ventilator. An inline fan listed to UL 705 for dryer ducts (a DEDPV) lets its maker's instructions set the maximum length. It needs a power supply and must be installed to those instructions. Ordinary inline booster fans are banned in dryer ducts by the 2021 and 2024 IRC. Many power ventilators are listed for electric dryers only, so check the listing if your dryer runs on gas.
Duct, outlet and joint rules
- Duct size and material: 4 in. nominal diameter, metal at least 0.0157 in. thick (No. 28 gage), with a smooth inside. Secured in place and supported at intervals of no more than 12 ft. For a gas dryer, the fuel gas chapter (Section G2439) asks for metal at least 0.016 in. thick, supported every 4 ft.
- Joints: each section's male end points in the direction of airflow, so lint slides past seams instead of catching on them.
- Fasteners: screws or rivets may stick into the duct no more than 1/8 in. Metal foil tape or clamps are the usual choice.
- Outlet: must end outside the building with a backdraft damper, and its opening must stay at least 12.5 sq in. Screens are not allowed. Unless the dryer's instructions say otherwise, keep it at least 3 ft from doors, windows and other openings into the house.
- Separate system: a dryer duct must carry moisture outdoors on its own. It may not join another exhaust duct, or end in an attic, crawl space, garage or wall cavity.
- Length label: under the 2015 to 2024 IRC, when the equivalent length is over 35 ft (allowed only under a dryer manual or a power ventilator), a permanent label or tag (often a sticker) within 6 ft of the duct connection must state it. The 2009 and 2012 editions require that label whenever the duct is concealed in the walls, floor or ceiling.
Why vent length matters
A dryer pushes hot, damp, lint-filled air out of the house. Every extra foot and every bend slows that air down. Slow air drops more lint inside the duct, drying takes longer, and the dryer runs hotter. Signs of a vent that is too long or clogged include loads that need two cycles, clothes that come out hot and damp, a laundry room that feels humid, and an outside flap that barely opens while the dryer runs.
NFPA estimates that US fire departments responded to an average of 13,820 home fires a year involving clothes dryers from 2014 to 2018. Failure to clean was the leading factor, at 32%. The U.S. Fire Administration also lists failure to clean as the leading factor, at 31% for 2018 to 2020. A longer vent collects lint faster, so it needs cleaning more often. Our dryer vent cleaning cost guide covers what a professional cleaning involves, and our dryer vent cleaning kit guide covers doing it yourself.
Older code editions
The 35 ft limit arrived with the 2012 IRC. The 2009 IRC set it at 25 ft, with the same fitting table. The 2006 IRC also allowed 25 ft, from the dryer location to the outside termination with the transition duct not counted, and charged a flat 5 ft for each 90° bend and 2 ft 6 in for each 45° bend, whatever the radius. A few areas still enforce an older edition, so pick yours in the calculator and it switches to those rules.
Frequently asked questions
What is the maximum length for a dryer vent?
How many feet does a 90 degree elbow add to a dryer vent?
Does the flexible hose behind the dryer count toward the vent length?
Can a dryer vent be longer than 35 feet?
Is flexible foil duct allowed for a dryer vent?
Can a dryer vent have a screen on the outside cover?
How often should a long dryer vent be cleaned?
How long can a dryer vent be without a booster fan?
Does a vertical dryer vent run count differently?
What is the maximum dryer vent length with 3 elbows?
How far does a dryer vent need to be from a window or door?
Do gas dryers have the same vent length limit?
Is semi-rigid aluminum duct allowed inside a wall?
Does the outside vent hood count toward dryer vent length?
Can a dryer vent end in the attic, garage or crawl space?
Codes and standards on this page
- IRC (International Residential Code): the model building code for one and two family homes and townhouses, published by the International Code Council (ICC). States and towns adopt an edition, often with changes. Dryer exhaust rules are in Section M1502, and gas dryers are also covered in Section G2439.
- Table M1502.4.6.1: the IRC table "Dryer exhaust duct fitting equivalent length", which lists how many feet of duct each elbow counts as. It was numbered M1502.4.5.1 in the 2015 and 2018 editions and M1502.4.4.1 in the 2009 and 2012 editions.
- UL 2158A: the UL safety standard for clothes dryer transition ducts. The flexible hose behind the dryer must be listed and labeled to it.
- UL 705: the UL safety standard for power ventilators. A fan installed in a dryer duct must be listed to it for dryer exhaust use.
- DEDPV (dryer exhaust duct power ventilator): the code term for a UL 705 listed inline fan made for dryer ducts. With one installed, its maker's instructions set the maximum duct length.
Sources and limits
This calculator follows the model International Residential Code. Your state or town may adopt it with changes, and the building official has the final say. Buildings under the International Mechanical Code, such as apartment and condo buildings with three or more units, use the same 35 ft limit and fitting table for household dryers. Commercial dryers follow separate rules. The figures were checked against these sources on November 21, 2026:
- International Residential Code 2021, Chapter 15 Exhaust Systems, Section M1502 (ICC, official text)
- IRC 2024 Section M1502 as adopted (UpCodes)
- IRC 2018 Section M1502 as adopted (UpCodes)
- IRC 2012 Section M1502 as adopted (UpCodes)
- IRC 2006 Chapter 15, Section M1502.6 (ICC, New Jersey edition)
- IRC 2021 Section G2439.7.4, gas clothes dryer exhaust duct length, as adopted (UpCodes)
- International Mechanical Code 2021, Section 504.9 as adopted (UpCodes)
- Whirlpool electric dryer installation instructions W10443041B, vent system chart
- Samsung DV45DG6000 dryer user manual, exhaust duct length table
- NFPA, Home Dryer Fires (2020 report, 2014 to 2018 data)
- U.S. Fire Administration, appliance and electrical fire safety
- NFPA, Clothes dryer safety tip sheet
- Maytag: Whirlpool Corp. gas and electric dryer instructions W10904260B, supplied for Maytag YMEDB765FC, box or louvered hood
- LG: LG venting help page, standard models, 4 in. wall cap
- GE: Electric dryer instructions Pub. 31-16135, 4 in. dampened hood
- Frigidaire: Installation manual A28709001 (2024), gas and electric, 4 in. hood
Spotted an error? Tell us and we will correct it.