Free calculator

Dryer Vent Length Calculator

Enter your straight duct and each elbow. The calculator adds them up the way an inspector does and shows how much room is left.

How long can a dryer vent be?

A home dryer vent can be up to 35 ft long under the International Residential Code (IRC, 2012 to 2024 editions), measured from where the transition hose connects to the duct to the outlet outside. Each standard 90° elbow counts as 5 ft of duct and each standard 45° elbow counts as 2 ft 6 in, so a vent with three standard 90° elbows can have at most 20 ft of straight duct. The flexible transition hose behind the dryer, up to 8 ft long, is not counted. Your dryer's installation manual can set a longer or shorter limit, and a UL 705 listed duct power ventilator can allow a longer run.

By The Appliance Aid Team · Code figures checked · Sources · How we work

Your vent run

  1. Start where the flexible hose behind the dryer joins the duct.
  2. Follow the duct to the cover outside, adding up each straight section.
  3. Count every turn. Results update as you type.
ft

Add up every straight section. Leave out the elbows (counted below) and the flexible hose behind the dryer.

Elbows and bends

Each elbow adds its equivalent length to the run. No radius on the label? Count it as a standard elbow.

+5 ft each
+2 ft 6 in each
Long radius (sweep) bends
+1 ft 9 in each
+1 ft each
+1 ft 7 in each
+1 ft each
+1 ft 6 in each
+9 in each

Radius is measured to the centerline of the bend.

What sets your maximum length?

Not sure? Keep the building code. If you have the dryer's installation manual, check its limit too. It can be longer or shorter than the code's, and a shorter one still applies to your dryer.

Town uses an older code?

Your local building department can tell you which edition it enforces.

Check the rest of your setup

Optional. These don't change the length, but an inspector will look at each one.

Main duct (the run to the outside)
Transition hose behind the dryer
ft
Outside vent cover
How the joints are held
Is the duct hidden in a wall, floor or ceiling?

How to measure dryer vent length

Where to measure a dryer vent A dryer connects to a wall duct with a flexible transition hose that is not counted. The measured run starts at the wall connection, goes up through a 90 degree elbow, runs across through a second 90 degree elbow, and ends at the outside hood. Dryer Transition hose not counted, max 8 ft Start here 90° elbow, 5 ft 90° elbow, 5 ft Outside wall Stop at the hood straight duct straight duct
Measure the straight duct from the wall connection to the outside hood, then add each elbow's allowance. This run has 2 standard 90° elbows, so it counts as its straight duct plus 10 ft.
  1. Find the starting point. Pull the dryer out and find where the flexible transition hose joins the duct at the wall or floor. Measure from there, not from the dryer.
  2. Measure each straight section. Use a tape on exposed duct in a basement, attic or utility room. For duct hidden in a wall, measure the route on both sides of the wall and add them.
  3. Count every elbow. Note whether each is a 90° or a 45°, and whether it is a standard adjustable elbow or a smooth long radius sweep.
  4. Stop at the outside hood. The hood itself adds nothing under the code.
  5. Enter the numbers in the calculator above.

What counts toward the length

Inspectors call it the equivalent length: the length of the duct from its connection to the transition duct to the outlet terminal outside, plus an allowance for every bend. Bends count because air loses pressure turning a corner, and a dryer's blower can only push so hard. A run of 20 ft with three standard 90° elbows counts as 35 ft, the same as 35 ft of straight duct.

Three things are left out of the count:

Dryer vent length with elbows: equivalent length chart

The IRC uses a table that depends on how tight the bend is. The same eight values appear in every edition from 2009 to 2024. A standard adjustable or mitered elbow counts as 5 ft. A smooth bend with a wider radius counts as little as 1 ft 6 in, which makes long radius sweeps a simple way to win back length.

Source: IRC Table M1502.4.6.1, Dryer exhaust duct fitting equivalent length, in the 2021 and 2024 editions. It is numbered M1502.4.5.1 in 2015 and 2018, and M1502.4.4.1 in 2009 and 2012.
Fitting (4 in. duct)Counts as (equivalent length)
90° elbow, standard (4 in. radius mitered or segmented)5 ft
45° elbow, standard (4 in. radius mitered or segmented)2 ft 6 in
90° smooth bend, 6 in. radius1 ft 9 in
45° smooth bend, 6 in. radius1 ft
90° smooth bend, 8 in. radius1 ft 7 in
45° smooth bend, 8 in. radius1 ft
90° smooth bend, 10 in. radius1 ft 6 in
45° smooth bend, 10 in. radius9 in

Add these lengths to your straight duct, or subtract them from 35 ft. Both give the same answer.

Close-turn or space-saver elbows are tighter than the 4 in. radius in the table, and the table has no row for them. This calculator counts each one as a standard elbow at 5 ft, which may be too generous. Ask your inspector for a firm ruling.

Maximum dryer vent length by number of elbows

Under the IRC, the longest straight duct a dryer vent can have is the length limit minus the allowance for its elbows. With standard 90° elbows that is 30 ft with one elbow, 25 ft with two, 20 ft with three and 15 ft with four.

Maximum straight 4 in. duct by number of 90° elbows, under each code edition. Each standard 45° elbow counts as half of a standard 90°.
90° elbowsIRC 2012 to 2024, standard elbowsIRC 2012 to 2024, 10 in. radius sweepsIRC 2006 and 2009, standard elbows
035 ft35 ft25 ft
130 ft33 ft 6 in20 ft
225 ft32 ft15 ft
320 ft30 ft 6 in10 ft
415 ft29 ft5 ft

Worked examples

Laundry closet on an outside wall. 6 ft of straight duct and two standard 90° elbows.

6 + 5 + 5 = 16 ft equivalent. That leaves 19 ft of the 35 ft limit.

Basement dryer venting up and out through the rim joist. 22 ft of straight duct, three standard 90° elbows and one 45°.

22 + 15 + 2.5 = 39 ft 6 in. That is 4 ft 6 in over. Swapping the four standard elbows for 10 in. radius sweeps brings it to 22 + 4.5 + 0.75 = 27 ft 3 in, which passes.

Second floor laundry venting through the roof. 28 ft of straight duct and two standard 90° elbows.

28 + 10 = 38 ft, 3 ft over the code limit. Swapping both elbows for 10 in. radius sweeps brings it to 28 + 3 = 31 ft, which passes.

Maximum dryer vent length by brand

The IRC lets the dryer's own installation instructions set the maximum length. The building official needs a copy of the instructions for your make and model at the inspection before the walls are closed. Most full size dryers allow longer runs than the 35 ft code default with 4 in. rigid metal duct. These figures come from each maker's published manual for the models shown:

Maximum 4 in. rigid metal duct length by number of 90° elbows, with the maker's recommended outside hood. Check the manual for your own model before you rely on a number.
Brand and manual0 elbows1 elbow2 elbows3 elbows4 elbows
WhirlpoolElectric dryer instructions W10443041B, box or louvered hood 64 ft54 ft44 ft35 ft27 ft
MaytagWhirlpool Corp. gas and electric dryer instructions W10904260B, supplied for Maytag YMEDB765FC, box or louvered hood 64 ft54 ft44 ft35 ft27 ft
LGLG venting help page, standard models, 4 in. wall cap 65 ft55 ft47 ft36 ft28 ft
GEElectric dryer instructions Pub. 31-16135, 4 in. dampened hood 90 ft60 ft45 ft35 ft25 ft
FrigidaireInstallation manual A28709001 (2024), gas and electric, 4 in. hood 90 ft60 ft*45 ft35 ftn/a
SamsungDV45DG6000 user manual (2024), 4 in. hood 80 ft68 ft57 ft47 ftn/a

n/a: not listed in that manual. *The Frigidaire manual prints 15.9 m next to 60 ft. The 60 ft figure matches GE's chart for the same setup, so the metric figure looks like the misprint. Some makers also sell long vent models rated for well over 100 ft. Their manuals list the exact figures.

Manufacturer tables work differently from the code. They list a maximum length for 0, 1, 2, 3 or 4 elbows, and often a separate column for each hood style. The elbows are already allowed for in each row, so you compare your duct length against the row that matches your setup. Choose My dryer's manual in the calculator and it does exactly that.

If you are buying a dryer for a long run, check the vent table in the installation instructions before you buy. They are usually posted on the maker's website under the model number.

How to fix a dryer vent that is too long

  1. Replace standard elbows with long radius sweeps. Under the 2009 to 2024 IRC, each 90° goes from 5 ft to as little as 1 ft 6 in, so three swaps win back 10 ft 6 in. The 2006 edition counts every bend the same, so this does not help there.
  2. Cut out bends. Two 45° elbows used to jog around an obstacle count as 5 ft. Rerouting to drop the jog is often less work than it looks.
  3. Exit through a closer wall. The shortest path to outside beats any fitting upgrade.
  4. Check the dryer's manual. Your model may allow the length you already have. If its limit is shorter than the code's, follow the manual.
  5. Add a dryer exhaust duct power ventilator. An inline fan listed to UL 705 for dryer ducts (a DEDPV) lets its maker's instructions set the maximum length. It needs a power supply and must be installed to those instructions. Ordinary inline booster fans are banned in dryer ducts by the 2021 and 2024 IRC. Many power ventilators are listed for electric dryers only, so check the listing if your dryer runs on gas.

Duct, outlet and joint rules

Why vent length matters

A dryer pushes hot, damp, lint-filled air out of the house. Every extra foot and every bend slows that air down. Slow air drops more lint inside the duct, drying takes longer, and the dryer runs hotter. Signs of a vent that is too long or clogged include loads that need two cycles, clothes that come out hot and damp, a laundry room that feels humid, and an outside flap that barely opens while the dryer runs.

NFPA estimates that US fire departments responded to an average of 13,820 home fires a year involving clothes dryers from 2014 to 2018. Failure to clean was the leading factor, at 32%. The U.S. Fire Administration also lists failure to clean as the leading factor, at 31% for 2018 to 2020. A longer vent collects lint faster, so it needs cleaning more often. Our dryer vent cleaning cost guide covers what a professional cleaning involves, and our dryer vent cleaning kit guide covers doing it yourself.

Older code editions

The 35 ft limit arrived with the 2012 IRC. The 2009 IRC set it at 25 ft, with the same fitting table. The 2006 IRC also allowed 25 ft, from the dryer location to the outside termination with the transition duct not counted, and charged a flat 5 ft for each 90° bend and 2 ft 6 in for each 45° bend, whatever the radius. A few areas still enforce an older edition, so pick yours in the calculator and it switches to those rules.

Frequently asked questions

What is the maximum length for a dryer vent?
A home dryer vent can be up to 35 feet long under the International Residential Code (IRC), editions 2012 through 2024, measured from where the duct connects to the transition hose behind the dryer to the outlet outside. Each standard 90 degree elbow counts as 5 feet and each standard 45 degree elbow as 2 feet 6 inches, so three standard 90 degree elbows leave 20 feet for straight duct. The transition hose is not counted. Your dryer's installation manual, or a UL 705 listed dryer exhaust duct power ventilator, can allow a longer run.
How many feet does a 90 degree elbow add to a dryer vent?
A standard 90 degree elbow (a 4 inch radius mitered or segmented elbow) counts as 5 feet of duct. Smooth long radius bends count for less: 1 foot 9 inches at a 6 inch radius, 1 foot 7 inches at 8 inches and 1 foot 6 inches at 10 inches. These values come from the IRC fitting table, numbered Table M1502.4.6.1 in the 2021 and 2024 editions.
Does the flexible hose behind the dryer count toward the vent length?
No. The code excludes the transition duct, the flexible piece that connects the dryer to the duct in the wall, from the maximum length. That piece must be a single length of no more than 8 feet, listed and labeled to UL 2158A, and it may not be concealed inside walls, floors or ceilings.
Can a dryer vent be longer than 35 feet?
Yes, in two cases. First, when the dryer's installation instructions allow a longer run and the building official is given a copy for that make and model. One Whirlpool electric dryer manual allows 64 feet of 4 inch rigid metal duct with no elbows and a box hood. Second, when a dryer exhaust duct power ventilator (DEDPV) listed to UL 705 is installed, its maker's instructions set the maximum length. Plain booster fans are banned in dryer ducts by the 2021 and 2024 IRC. Otherwise 35 feet, less the elbow allowances, is the limit.
Is flexible foil duct allowed for a dryer vent?
Only as the transition duct between the dryer and the wall, and only if it is listed to UL 2158A, 8 feet or shorter and left in view. The duct itself must be metal with a smooth inside, at least 0.0157 inch thick (28 gauge). White plastic (vinyl) hose is not allowed anywhere. Some dryer manuals go further: Frigidaire's says not to use flexible foil at all, so check yours.
Can a dryer vent have a screen on the outside cover?
No. The IRC does not allow screens at a dryer exhaust outlet, because lint clogs the mesh and blocks airflow. The outlet needs a backdraft damper, a flap that closes when the dryer is off, to keep out rain, cold air and pests.
How often should a long dryer vent be cleaned?
Clean the lint screen before or after every load. NFPA advises cleaning lint out of the vent pipe at least once a year, or more often if drying starts to take longer. Longer runs and runs with several elbows trap lint faster, so check them sooner if clothes come out hot and damp or the outside flap barely opens while the dryer runs.
How long can a dryer vent be without a booster fan?
Up to 35 feet under the IRC, less 5 feet for each standard 90 degree elbow and 2 feet 6 inches for each standard 45 degree elbow, or the maximum in your dryer's installation manual. Plain booster fans are banned in dryer ducts by the 2021 and 2024 IRC, so a longer run needs either a dryer whose manual allows it or a UL 705 listed dryer exhaust duct power ventilator.
Does a vertical dryer vent run count differently?
No. The IRC sets one maximum length for the whole duct and does not treat vertical runs differently from horizontal ones. A run that goes up through a wall or out the roof counts the same way: its straight sections plus the allowance for each elbow.
What is the maximum dryer vent length with 3 elbows?
With three standard 90 degree elbows, a dryer vent can have up to 20 feet of straight duct under the IRC, because each elbow counts as 5 feet of the 35 foot limit. With three 10 inch radius sweeps, which count as 1 foot 6 inches each, the straight duct can be 30 feet 6 inches. Your dryer's manual may allow more: one Whirlpool chart allows 35 feet of rigid duct with three elbows and a box hood.
How far does a dryer vent need to be from a window or door?
At least 3 feet in any direction from openings into the building, such as doors, windows and soffit vents, unless the dryer's installation instructions give a different distance. This rule is in IRC Section M1502.3.
Do gas dryers have the same vent length limit?
Yes. The IRC's fuel gas chapter repeats the same rule for gas dryers in Section G2439.7.4.1: 35 feet from the transition duct connection to the outlet, reduced by the same elbow allowances in Table G2439.7.4.1. Its duct rules are a little stricter: metal at least 0.016 inch thick, supported every 4 feet. A gas dryer's installation manual can also set its own maximum. Check any duct power ventilator's listing before using one: many, including Suncourt's, are listed for electric dryers only.
Is semi-rigid aluminum duct allowed inside a wall?
No. Semi-rigid aluminum is a transition duct, so it may only connect the dryer to the duct, in one piece up to 8 feet long, and it may not be concealed inside walls, floors or ceilings. The duct inside the wall must be metal with a smooth inside.
Does the outside vent hood count toward dryer vent length?
Not under the IRC, which gives the outlet hood no length allowance. Dryer makers often do count it: their vent tables list a separate maximum for each hood style, and one Whirlpool chart allows 6 feet less with an angled hood than with a box hood.
Can a dryer vent end in the attic, garage or crawl space?
No. The IRC requires a dryer exhaust duct to carry moisture outdoors and end outside the building, so it may not end in an attic, crawl space, garage or anywhere inside the house.

Codes and standards on this page

Sources and limits

This calculator follows the model International Residential Code. Your state or town may adopt it with changes, and the building official has the final say. Buildings under the International Mechanical Code, such as apartment and condo buildings with three or more units, use the same 35 ft limit and fitting table for household dryers. Commercial dryers follow separate rules. The figures were checked against these sources on November 21, 2026:

Spotted an error? Tell us and we will correct it.

Related dryer guides