Appliance Aid takes part in the Amazon Associates programme. Some links on this page are affiliate links, and a qualifying purchase earns us a commission. Your price is unchanged.
🏆 RECOMMENDED PART
DC47-00016A Dryer Thermal Fuse Kit by Techecook - DC47-00016A Thermal Fuse & DC96-00887A Thermostat & DC32-00007A Thermistor & DC47-00018A H
- ✔✔【ITEM SPECIALITY 】:▶DC47-00016A Dryer Thermal Cut-Off Thermostat shuts off the motor when dryer overheats,which is located on the blower housing. ▶DC96-00887A Thermal Fuse with Bracket will shuts off the heat if the...
- ✔✔【PACKAGE INCLUDES】:1 x DC47-00016A Thermal Fuse, 1 x DC96-00887A Thermostat, 1 x DC32-00007A Thermistor, 1 x DC47-00018A High Limit Thermostat. If your dryer has the following problems: cannot dry properly, cannot s...
- ✔✔【WIDE COMPATIBLE】:Dryer thermal fuse kit fits for most top brands like Ken. more and Sam-sung dryer. ►Replaces part numbers: ▶DC32-00007A:N3S1-K41, N3SI-K41, 2068429, AP4201716, PS2461163, EAP2461163. ▶DC96-00887A:W...
- ✔✔【DIY INSTALLATION】:Unplug and turn off the power supply to the drying machine before making any repairs. DC47-00016A Dryer Thermal Fuse Kit is made with high quality materials. Before leaving the factory it has been...
- ✔✔【WORRY-FREE SHOPPING】:If the DC47-00016A Sam-sung Dryer Thermal Fuse Kit has any quality problem or other reasons, Please contact customer service in time, we will provide you with after-sales service to solve your ...
What the DC47-00016A does
A thermal fuse is a safety device in a dryer designed to prevent overheating. It is a one-time fuse that permanently breaks the electrical circuit if the internal temperature exceeds a safe limit.
Symptoms when this part fails
- Dryer not heating
- Dryer not starting
- Dryer runs but clothes remain wet
- No power to the dryer
Compatibility
Fits the Bosch family. Specifically:
- Any unit originally equipped with OEM part number(s): DC96-00887A, DC32-00007A.
- Check the model/rating plate inside your appliance and compare it against the fitment table on the product listing before ordering — this guide does not list specific compatible models because Amazon does not provide verified fitment data through this pipeline.
Also replaces: DC96-00887A, DC32-00007A
Tools you'll need
- Screwdriver set
- Nut driver set
- Pliers
- Multimeter
Difficulty: Moderate · Time: 30-60 minutes
How to install the DC47-00016A, step by step
- Disconnect the dryer from power and gas supply (if applicable).
- Access the thermal fuse, typically located near the blower housing or heating element.
- Carefully disconnect the wires attached to the old thermal fuse.
- Remove any mounting screws or clips securing the old fuse.
- Install the new thermal fuse, ensuring it is securely mounted.
- Reconnect the wires to the terminals of the new fuse.
- Reassemble any dryer panels or components that were removed.
- Restore power and test the dryer's operation.