Compressor start relay: why the fridge clicks but will not cool
The start relay is one of the cheapest parts in the compressor circuit and a common reason a fridge clicks every few minutes without cooling. It plugs onto the compressor terminals, so you can swap it without opening the sealed system.
Appliance Aid takes part in the Amazon Associates programme. Some links on this page are affiliate links, and a qualifying purchase earns us a commission. Your price is unchanged.
Symptoms that point to the compressor start relay
Both sections warm, light still on
Check first: Clean the condenser coils and pull the fridge a few inches from the wall. Then listen: a running compressor with a silent condenser fan points one way, a clicking compressor points another.
Parts to check for this problem, in order: Condenser fan motor → Compressor start relay → Evaporator fan motor
Clicks every few minutes, compressor won't stay on
Check first: Make sure the fridge has its own outlet with no extension cord. Low voltage can make a healthy compressor click off.
Parts to check for this problem, in order: Compressor start relay → Condenser fan motor
What the compressor start relay does and how it fails
Gives the compressor the extra kick it needs to start. It plugs onto the side of the compressor.
Most modern relays use a ceramic PTC disc that cracks or burns out with age and heat. The compressor then tries to start, the overload trips, and you hear a click every few minutes. A failed overload, low outlet voltage, or a seized or shorted compressor cause the same symptom, and a new relay will not fix a dead compressor. Many LG and Samsung refrigerators use inverter or linear compressors driven by a board, with no start relay at all.
How to test the compressor start relay
Short version: A click every few minutes with the compressor never staying on is the classic sign. Pull the relay and check it against the tech sheet. A burnt smell or rattle inside the relay also points to it.
- Unplug the refrigerator, pull it out and remove the lower back panel.
- Remove the relay cover and pull the relay straight off the compressor pins, noting its orientation.
- Check for a burnt smell, scorched plastic or a rattle inside.
- Measure across the start and run sockets. Most PTC relays read low resistance at room temperature, often a few ohms. The tech sheet lists the exact value. Open means the relay is bad.
- If the relay tests fine, the overload or compressor may be at fault. Compressor diagnosis is a job for a licensed technician.
Refrigerator compressor start relay part numbers
Each number below was checked against its live Amazon listing. Find your number on the old part or in your model's parts list, then match it here.
| Part number | Made for | Also replaces | Buy |
|---|---|---|---|
| 5304529507 | Frigidaire | None listed | View on Amazon |
| WR09X10107 | GE | WR55X24064 | View on Amazon |
| WPW10662129 | Maytag Whirlpool part number |
0303053, 0313053, 18516-3, 2-35154-010 | View on Amazon |
| W10613606 | Whirlpool | W10416065, 67003186, 14217273, 67003764 | View on Amazon |
Not your number? Search Amazon and add your model number, or use the model number search.
Buying the right compressor start relay
Order by the refrigerator model number and compare the number on the old relay. Relays are matched to the compressor, so a universal relay that fits the pins may not suit it. Kits with a new overload and harness make sense when the old overload is also suspect.
Where to find the model number: Look on the inside wall of the fresh food section, near the top or beside the crisper drawers. On some models the label is on the ceiling of the fridge or inside the freezer door.
How to replace the compressor start relay
Safety: Unplug the refrigerator before you remove any panel. Leave sealed system work, such as the compressor and refrigerant lines, to a licensed technician.
- Unplug the refrigerator and remove the lower back access panel.
- Photograph the relay, overload and wiring before you disconnect anything.
- Remove the cover or clip, pull the relay off the pins and disconnect its wires.
- If your kit includes an overload or capacitor, fit those too, following the kit's diagram.
- Press the new relay onto the pins in the same orientation and reconnect the wires as shown in your photo.
- Refit the cover and panel, plug in, and listen for the compressor to start and keep running. If it still clicks off, call a technician.
Questions about the compressor start relay
Can I bypass the start relay to see if the compressor runs?
No. The relay and overload protect the compressor and wiring. Testing a compressor directly is work for a licensed technician.
Why does the compressor not start right after a power cut?
A PTC relay needs a few minutes to cool before it can start the compressor again, so a short delay is normal.
Repair guides
- Refrigerator Not Cooling But Light Is On? DIY Troubleshooting Guide
- How to clean refrigerator condenser coils: Whirlpool, LG, Samsung, Haier and more
- How to Clean Refrigerator Coils for Optimal Efficiency
- Refrigerator compressor not running? Test the start relay first (it costs $8)
- Refrigerator Compressor Replacement Cost: Repair vs. New Fridge
- Refrigerator Compressor Replacement Cost: DIY vs. Pro
Other refrigerator parts to check
Part numbers on this page were checked against their Amazon listings on November 1, 2026. Listings change, so confirm your model number on the listing before you order. Researched from manufacturer service documents, parts listings and owner reports, not hands-on repairs. How we work.